| **How to Get an SVID Value from the Tool** | **How to Get an SVID Value from the Tool** | ||
| - | # Start the SECS Tester | + | - Start the SECS Tester |
| - | # Double-Click on "Set Up Communications to Tool" to open the Communications Setup Dialog | + | |
| - | * The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup. | + | - The default tool configuration will be shown. You can change the tool name so that this configuration will be saved as a new tool setup. |
| - | * Enter the HSMS Port (or SECS I Port, a port number < 255) | + | - Enter the HSMS Port (or SECS I Port, a port number < 255) |
| - | * Enter the Device ID | + | - Enter the Device ID |
| - | * Enter the new tool name | + | - Enter the new tool name |
| - | * Save the configuration by pressing the Save button, then the close button | + | - Save the configuration by pressing the Save button, then the close button |
| - | # Select the new tool configuration from the combo box. You should see the tool configuration printed out in the text field on the right. | + | |
| - | # Connect to the tool | + | - Connect to the tool |
| - | * Press " | + | - Press " |
| - | * If the communications was successful you will see a response from the tool. | + | - |
| - | # Go online-remote with the tool | + | |
| - | * Be sure the tool is ready to go online with this host and is allowing remote communications. | + | - Be sure the tool is ready to go online with this host and is allowing remote communications. |
| - | * Press " | + | - |
| - | * If the online request was successful you will see an S1F18 response with a reply other than " | + | - If the online request was successful you will see an S1F18 response with a reply other than " |
| - | # Once the tool is ONLINE-REMOTE you can get a list of SVIDs and request the current value of any of them. | + | |
| - | | + | - Double-Click "Check SVID Values" |
| - | | + | - Click on the "Get List of SVIDs" button to send an S1F11 to the tool |
| - | | + | - If the tool has SVIDs, these VIDs will show up in the SVID List combo box, alphabetically by SVID name |
| - | | + | - Select an SVID and press the "Get Current Value" to send an S1F3 to the tool |
| - | | + | - The current value will be displayed below the "Get Current Value" button |