opcda_server_integration_guide
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| opcda_server_integration_guide [2023/02/15 10:22] – wikiadmin | opcda_server_integration_guide [2023/03/02 16:20] (current) – wikiadmin | ||
|---|---|---|---|
| Line 46: | Line 46: | ||
| The batch file used to start the server must be run in with admin privileges. Details on how to do this can be found [[https:// | The batch file used to start the server must be run in with admin privileges. Details on how to do this can be found [[https:// | ||
| - | The basis steps are: | + | The basic steps are: |
| - | > | ||
| - | > | ||
| - | > | ||
| - | > | ||
| > How to run a batch file as Administrator in Windows 10? | > How to run a batch file as Administrator in Windows 10? | ||
| > | > | ||
| Line 65: | Line 61: | ||
| > Then you need to use that shortcut to start the software, not the actual batch file. | > Then you need to use that shortcut to start the software, not the actual batch file. | ||
| + | When the server starts correctly you will see the message " | ||
| + | |||
| + | {{: | ||
| + | |||
| + | If you reach this stage, but your OPC client still reports that the server is not registered copy this text into a file called " | ||
| + | |||
| + | < | ||
| + | REGEDIT4 | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}] | ||
| + | @=" | ||
| + | " | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}\Implemented Categories] | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}\Implemented Categories\{63D5F430-CFE4-11D1-B2C8-0060083BA1FB}] | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}\Implemented Categories\{63D5F432-CFE4-11D1-B2C8-0060083BA1FB}] | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}\LocalServer32] | ||
| + | |||
| + | [HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}\ProgID] | ||
| + | @=" | ||
| + | </ | ||
| + | |||
| + | Then double click on " | ||
| + | |||
| + | If you want to unregister the OPCDA Server you can copy ithis nto a UnRegisterErgoTechOPCDA.reg and run it: | ||
| + | < | ||
| + | REGEDIT4 | ||
| + | |||
| + | [-HKEY_CLASSES_ROOT\CLSID\{F2120BB1-5FB8-480D-BAEE-06B9F3650AB0}] | ||
| + | </ | ||
| + | | ||
| + | If you still cannot connect, set the " | ||
| + | Navigate to "DCOM Config" | ||
| + | {{: | ||
| + | Find the ErgoTech OPCServer. | ||
| + | {{: | ||
| - | When you start the OPCDA Server on a 64-bit system you will see an error noted about the UnilogServer FAILED. This can be ignored. | + | When you start the OPCDA Server on a 64-bit |
| < | < | ||
| Line 77: | Line 112: | ||
| Creating UnilogServer StartedmanageOPCDAcat | Creating UnilogServer StartedmanageOPCDAcat | ||
| | | ||
| - | | + | |
opcda_server_integration_guide.1676474533.txt.gz · Last modified: by wikiadmin